Corrosion Protection

The primary purpose of mechanical plating processes is to enhance the corrosion protection of the parts plated. Zinc and other active metals, such as cadmium and aluminum, protect the underlying ferrous substrates by a process called "sacrificial protection," also known as "cathodic protection." PS&T's products offer unparalleled corrosion protection.

Sacrificial Protection Explained

In this method of corrosion protection, the metals that are more active (chemically speaking, with more negative potentials or higher in the electromotive series), such as zinc, protect those that are less active or more noble by "sacrificing" themselves to protect the underlying more noble base metal. This process works effectively even if the sacrificial metal coating is slightly damaged.

Corrosion Rates

The corrosion protection offered by zinc deposits is dependent upon three factors: coating thickness, post-plate treatments, and environmental exposure. Zinc plating (without chromates or passivates) corrodes at rates which are dependent upon the severity of the environment, as shown in the summary presented below. There is a significant body of data on local corrosion rates currently available.
Because the corrosion protection offered by sacrificial deposits is so lengthy, accelerated tests are routinely used to predict the long-term effectiveness of the deposits. The two most common tests used are the ASTM G87 Moist SO2 Test (Kesternich Test) and the ASTM B117 Salt Fog (Salt Spray) Test. In this latter test (which is much more common), a fog is generated from a 5 percent neutral (i.e., a pH of 7) salt (sodium chloride) solution. The parts are then evaluated for the first appearance of white corrosion products ("white rust" or oxides of zinc) and (later in the test) the formation of red rust, or base metal corrosion.
Atmosphere
Mean Corrosion Rate
Industrial
5.6 Microns (0.22 mils) per Year
Urban Nonindustrial
1.5 Microns (0.06 mils) per Year
Suburban
1.3 Microns (0.05 mils) per Year
Rural
0.8 Microns (0.03 mils) per Year
Indoors
Considerably Less Than 0.5 Microns (0.01 mil) per Year
(Source: ASTM B695)

How Long Do Mechanically Plated Deposits Last in the Salt Spray Test?

Zinc Thickness
Salt Spray Protection
0.00012" (3 Microns)
24 Hours
0.00024" (6 Microns)
48 Hours
0.00035" (9 Microns)
72 Hours
0.00047" (12 Microns)
96 Hours
0.00059" (15 Microns)
120 Hours
0.00098" (25 Microns)
192 Hours
0.00157" (40 Microns)
250 Hours
0.00197" (50 Microns)
300 Hours
Sources: American Society for Testing and Materials (ASTM B695)

Post-Treatment Coatings

In general, post-treatments will add corrosion protection as follows:
Clear Chromates (Hex)
12-24 Hours
Trivalent Passivates
12-96 Hours
Yellow Chromates
96-168 Hours
Olive Drab Chromates
96-192 Hours
No Rinse Hyperguard
96-192 Hours
Hyperguard™ 326™
240+ Hours
Mechanical plating and mechanical galvanizing offer a proven means of protecting ferrous substrates from environmental corrosion. The nature of the deposit can be adjusted to provide protection from even the most severe environmental conditions.

Increase Your Protection with Sealants

Proprietary sealants (such as PS&T's Hyperseal®) can be applied over chromates and passivates to significantly enhance the protection of the chromate or passivate. The additional protection offered by such products is typically 100 to 200 additional hours, although exceptionally lengthy results have been reported.
The best and longest results are achieved over hexavalent chromates or those trivalent passivates that generate the most hexavalent chromium (e.g. Hyperguard™ 326™).

How Hexavalent Chromates and Trivalent Passivates Work

Chromates protect the underlying deposit by delaying the onset of the white corrosion products. The chromating processing is technically called a "conversion process." In this process, the parts are dipped into a solution containing chromates, and the solution "converts" the topmost part of the zinc into zinc chromate. This zinc chromate is a highly effective corrosion inhibitors and the process binds it tightly to the surface of the zinc. It is important to recognize that the application of the chromate conversion coating is the most cost effective corrosion protection one can buy. Trivalent passivates, as reported in Plating and Surface Finishing in October 2007, function by generating hexavalent chromium during the corrosion process. They are applied in the same process of dipping the parts, but there is no conversion at the topmost part of the zinc coating. In essence, it is just another layer over the top of the zinc coating. However, the thicker this layer is, the more hexavalent chromium will be produced and thus the more corrosion protection the underlying deposit will have. Some common thin build trivalent passivates are: Tridescent™ (Luster-On Products), Chromiting™ (Sur-Tech International) or HyproBlue™ (Pavco). These will add about 100 hours of corrosion protection whereas the Hyperguard 326 (a thick build passivate) can add over 240 hours.
To print this page, click below for pdf:
Corrosion Protection
Plating Systems & Technologies, Inc.
HomeSimple & Reliable Process8 Reasons for Plating7 Reasons for GalvanizingCorrosion ProtectionHydrogen EmbrittlementSpecificationsHistory of Mechanical PlatingGlass Impact MediaGlass Bead SizesEquipmentPlaters and GalvanizersAbout UsContact
317 N Mechanic Street, Jackson, MI 49201Phone: (517) 783-4776
Copyright © 2025 Plating Systems & Technologies, Inc. All Rights Reserved.

We use cookies to enable essential functionality on our website, and analyze website traffic. By clicking Accept you consent to our use of cookies. Read about how we use cookies.

Your Cookie Settings

We use cookies to enable essential functionality on our website, and analyze website traffic. Read about how we use cookies.

Cookie Categories
Essential

These cookies are strictly necessary to provide you with services available through our websites. You cannot refuse these cookies without impacting how our websites function. You can block or delete them by changing your browser settings, as described under the heading "Managing cookies" in the Privacy and Cookies Policy.

Analytics

These cookies collect information that is used in aggregate form to help us understand how our websites are being used or how effective our marketing campaigns are.